We can offer a wide range of Posca Pens that offer great permanent marking on paper, glass, plastic and fabric. For further information on the specifications, please visit our website.
Electro conductive storage containers for the safe storage of static sensitive components.
Notes:
Designed to Ministry of Defence specification 59/98 and BS EN 100015
SMT magazine racks are designed for the manufacture, assembly, storage and transfer of PCB
We can assist and advise on a vast range of cross linked closed cellfoams for specialist applications please contact one of ourexperienced sales team.
Technical Specification for Low Density Foam (High density available on request):
Property: Test Method: Requirement:
Foam Type N/A Polyether polyurethane foam impregnated
with flexible conductive latex
Density (kg/m3) BS 4443 Pt1 Method 2 24 minimum
Tensile Strength (KPa) BS 4443 Pt1 Method 3A 70 minimum
Elongation @ Break (%) BS 4443 Pt1 Method 3A 100 minimum
Loss in Tensile Strength After Heat Ageing (%) BS 4443 Pt1 Method 3A
140oC for 16 hours
30% Max Loss
Loss in Tensile Strength After Humidity
Ageing (%)
BS 4443 Pt1 Method 3A
105oC for 3 hours
30% Max Loss
Compression Set (50% Compression) BS 4443 Pt1 Method 3A 30% Max Loss
Volume Resistivity (ohms/m) BS 2044 Pt1 Method 3
(100V)
250 maximum
Surface Resistivity (K ohms) Megger BM201
(100V)
<20
Compression Deflection at 50% Compression BS 4443 Pt1 Method 5A 3.3 KPa (Typical Value)
Fibreboard Waste Bin
Polypropelene Waste Bin
Homogeneous, non-amine antistatic polythene film which is effective at low relative humidities (less than 12%). Specifically designed for the particular needs of the electronics industry, it meets Type II Mil B 81705C.
These bottles will dissipate a static charge of +5000V in less than 2 seconds at 40% relative humidity. By their chemical nature, they will not have any chemical reactivity with solvents as TCE or alcohol. The pH of the deionised water solutions tested were the same before and after a seven day period. No colour or physical change was noted for any solvents tested.